Characteristics & Main Applications
KLINGER Graphite Laminate PSM features a perforated 'tanged' metal reinforcement providing improved blow-out resistance, particularly under cycling loads.

Material
The graphite is a pure expanded graphite supplied with an Anti-Stick (AS) surface which provides optimal sealing features of graphite without the hassle of graphite sticking to flanges. Suited to use in heat-exchangers, liquid gas plants, exhaust manifold gaskets, petroleum refining, severely corrosive and aggressive media, sensitive flanges (enamel, glass, graphite) and steam.

The Anti-stick coating on both sides aids flange separation, reducing installation time. It also removes the need for application of grease or sealants which may cause gasket failure.

KLINGERgraphite PSM-AS is now Certified Fire Safe! Can be supplied without Anti Stick as KLINGER PSM-G

Click to Download Technical Data Sheet
Click to Download MSDS (Material Safety Data Sheet)

Function & Durability
The performance and service life of KLINGER gaskets depend in large measure on proper storage and fitting, factors beyond the manufacture's control. We can, however, vouch for the excellent quality of our products. With this in mind, please also observe our installation instructions.


Fire-Safe - Download PDF